System Metrics

Annual Production

0

x 1000 kWh (Units)

Performance Ratio

0

Percentage

Specific Generation

0

kWh/kWp/year

Module DC Nameplate

503.04 kWp

AC Nameplate

500.00 kW

DC-AC Ratio

1.01

Weather Dataset

Meteonorm

Components

Your installation uses latest technology in solar

Modules

Waaree Arka Series WSMD – 515 to 545 WSMD
545 – 923.00 No

Inverters

HT SeriesW3 – 100K Waaree – 5.00 No.

Walkways

Premium Walkways – 149.83 m

Handrail

Premium Handrail – 222.45 m

Structure

Premium Structure

DCDB

PREMIUM – 5.00 No.

Expected Annual Production

During the first year of operations, your system is expected to produce 655.48 x 1000 kWh over the year

Expected average generation of the system

54,623.59 kWh/month

Yearly degradation rate

0.6%/year

Field Segments

NameOrientationTiltAzimuthRow SpacingFrame SizeModulePowerSolar Access
Subarray #100Portrait180.89°0.025 m3x257540.88 kWp95.42%
Subarray #100Portrait180.89°0.025 m3x25375204.38 kWp95.42%
Subarray #26Portrait180.51°0.025 m3x195731.07 kWp95.42%
Subarray #26Portrait180.51°0.025 m3x195731.07 kWp95.42%
Subarray #367Portrait181.06°0.025 m1x353519.08 kWp96.57%
Subarray #367Portrait181.06°0.025 m1x121.09 kWp95.42%
Subarray #367Portrait181.06°0.025 m1x5105.45 kWp95.77%
Subarray #367Portrait181.06°0.025 m1x5105.45 kWp95.99%
Subarray #367Portrait181.06°0.025 m1x5105.45 kWp96.12%
Subarray #367Portrait181.06°0.025 m1x5105.45 kWp96.03%
Subarray #367Portrait181.06°0.025 m1x121.09 kWp94.30%
Subarray #933Portrait15°180.37°1.802 m1x72111.45 kWp98.69%
Subarray #933Portrait15°180.37°1.802 m1x773.82 kWp98.65%
Subarray #933Portrait15°180.37°1.802 m1x72111.45 kWp98.63%
Subarray #933Portrait15°180.37°1.802 m1x773.82 kWp98.65%
Subarray #933Portrait15°180.37°1.802 m1x7147.63 kWp98.72%
ArrayJanFebMarAprMayJunJulyAugSeptOctNovDec
10084859299100100100100959085
13184859299100100100100959085
688485929910010010010095908582
698485929910010010010095908582
44687889410010010010010096928785
4478484939910010010010096908583
4488486939910010010010095918683
44985879310010010010010096918683
45085879310010010010010096918784
45185879310010010010010096918684
4527983929910010010010095898279
105292949710010010010010099969392
105392949710010010010010099969391
105492949710010010010010099969391
105592949710010010010010099969391
105692949710010010010010099969392
105793949710010010010010099969392
106092939710010010010010099969391
106192939710010010010010099969391
106292939710010010010010099969391
106392939710010010010010099969391
106493949710010010010010099969392
106592939710010010010010099969391

Shading Analysis

Conclusion: Modules are shadow free for 99.91% of solar time throughout the year.

Irradiance Map/ Solar Access

Irradiance Map

Solar Access

System Production Losses

Loss in generation predicted due to environmental and electrical factors

Environmental Impact

You are contributing to solve Earth’s biggest problem – Climate Change.

Carbon Dioxide Offset

0

x 1000 kWh (Units)

Equivalent Acres of Forest

0

x 1000 kWh (Units)

Coal Burn Avoided

0

x 1000 kWh (Units)

Equivalent Number of Trees Planted

1,78,539.00 trees

Petrol Consumption Avoided

46,01,512.02 litres

Equivalent Kilometers Driven

4,24,22,063.00 kms